跳至主要内容

BU04 LoRa AT Command Troubleshooting

Module Not Responding

SymptomFix
No response to ATBaud rate mismatch — default 9600, try 115200
Garbage responseSend AT followed by CR+LF (not just AT)
BUSY after every cmdSend AT+RESET first, wait 2s

Common AT Commands

CommandFunction
ATTest communication
AT+ADDR?Read device address
AT+CH=8Set channel to 8
AT+POWER=22Set TX power to 22 dBm (max)
AT+RELAY=1,1Turn relay 1 ON
AT+RELAY=1,0Turn relay 1 OFF

Relay Not Switching

  1. Relays need separate power supply — the LoRa module does not power the coil
  2. Try AT+RELAYMODE=1,1 to invert logic (active HIGH vs LOW)
  3. BU04 relays rated 10A/250VAC — exceeding this welds contacts

Range Issues

  • Set TX power to max: AT+POWER=22
  • Upgrade spring antenna to external SMA for >500m range
  • Keep antenna away from metal enclosures and relay wiring